<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-17 16-38-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 70 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.1 kHz 84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19059 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,5 dBr 1,80 dBr 3,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Perlman Itzhak (Viulu) & Sanders Samuel (Piano), Sanders Samuel "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/01/17 16.37.01 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,5 dBr MIN: -0,5 dBr AVE: 1,80 dBr % above 12,2 dBr: 0,0 Last value: 2,1 dBr (2025/01/17 16.37.01) 16.24 16.26 16.28 16.30 16.32 16.34 16.36 -1 0 1 2 3 4 Pm [dBr]